{"id":20881,"date":"2023-11-13T21:21:13","date_gmt":"2023-11-13T21:21:13","guid":{"rendered":"https:\/\/hvacrheritage.ca\/?post_type=cpt_portfolio&#038;p=20881"},"modified":"2023-11-14T20:29:06","modified_gmt":"2023-11-14T20:29:06","slug":"radiant-heat-sensor","status":"publish","type":"cpt_portfolio","link":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/portfolio\/radiant-heat-sensor\/","title":{"rendered":"Radiant heat sensor"},"content":{"rendered":"<h3 class=\"wp-block-heading\">Pressure Atomizing Oil Burner Equipment and Systems \u2013 Fuel Flow and Combustion Controls<\/h3>\n\n\n\n<p>The \u201cProtectostat\u201d, a late 1940\u2019s radiant heat sensor for combustion safety control. It would set new standard for combustion safety for higher firing rate, oil atomizing heating systems found in large Canadian estate homes, institutions and small industrial applications. Sited directly on the fire, it used a black metal diaphragm to mechanically actuate a low voltage control system through a Minneapolis Honeywell \u201cProtectorelay\u201d, Minneapolis Honeywell, Type A, Circa 1948.<\/p>\n\n\n\n<p><strong>Features:<\/strong><br>\u2013 Handsome corporate name plate and logo in red, black and chrome<\/p>\n\n\n\n<p><strong>Technical Significance:<\/strong><br>\u2013 Mounted adjacent to the burner fire tube, the device immediately sensed the radiant heat of combustion, providing here-to-for unheard of rapid response needed for the safe and satisfactory operation of larger oil fired boilers and furnaces, operating in the range of 3 to 12 gallons per minute of number 2 or 3 fuel oil.<br>\u2013 The Protectostat operated a Minneapolis Protectorelay, consisting of electro-magnetic switches and a thermal safety, automatic cut out timing device.<br>\u2013 The Protectostat with Protectorelay would become the standard of the industry for institutional and small commercial and industrial, automatic oil fired systems until the introduction of photo-electric eye, electronic sensing technology in the 1950\u2019s, see reference.<br>\u2013 These embryonic, electric automated systems were representative of the early introduction of complex systems into Canadian homes and places of business. See Note #2<\/p>\n\n\n\n<p><strong>Industrial Significance:<\/strong><br>\u2013 The potential explosive power of several gallons per minute of high pressure vapourized fuel oil being sprayed into a combustion chamber is awesome and a source of fear to system owners, operators and service people alike. The importance of fast response for safety shut down in case of delayed ignition on unattended, automatic systems is paramount. The development of the radiant heat sensor opened up new applications for automatic operation of boilers, where operating engineers in constant attendance became unnecessary under certain conditions.<\/p>","protected":false},"excerpt":{"rendered":"<p>The \u201cProtectostat\u201d, a late 1940\u2019s radiant heat sensor for combustion safety control. It would set new standard for combustion safety for higher firing rate, oil atomizing heating systems found in large Canadian estate homes, institutions and small industrial applications. Sited directly on the fire, it used a black metal diaphragm to mechanically actuate a low voltage control system through a Minneapolis Honeywell \u201cProtectorelay\u201d, Minneapolis Honeywell, Type A, Circa 1948.<\/p>","protected":false},"author":1,"featured_media":20882,"comment_status":"closed","ping_status":"closed","template":"","cpt_portfolio_group":[209,211,206],"class_list":["post-20881","cpt_portfolio","type-cpt_portfolio","status-publish","has-post-thumbnail","hentry","cpt_portfolio_group-heating","cpt_portfolio_group-industrial","cpt_portfolio_group-residential"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Radiant heat sensor - HVACR Heritage Centre<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/portfolio\/radiant-heat-sensor\/\" \/>\n<meta property=\"og:locale\" content=\"fr_CA\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Radiant heat sensor - HVACR Heritage Centre\" \/>\n<meta property=\"og:description\" content=\"The \u201cProtectostat\u201d, a late 1940\u2019s radiant heat sensor for combustion safety control. It would set new standard for combustion safety for higher firing rate, oil atomizing heating systems found in large Canadian estate homes, institutions and small industrial applications. Sited directly on the fire, it used a black metal diaphragm to mechanically actuate a low voltage control system through a Minneapolis Honeywell \u201cProtectorelay\u201d, Minneapolis Honeywell, Type A, Circa 1948.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/portfolio\/radiant-heat-sensor\/\" \/>\n<meta property=\"og:site_name\" content=\"HVACR Heritage Centre\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-14T20:29:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2023\/11\/artif_233.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"402\" \/>\n\t<meta property=\"og:image:height\" content=\"242\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimation du temps de lecture\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/radiant-heat-sensor\\\/\",\"url\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/radiant-heat-sensor\\\/\",\"name\":\"Radiant heat sensor - HVACR Heritage Centre\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/radiant-heat-sensor\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/radiant-heat-sensor\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/artif_233.jpg\",\"datePublished\":\"2023-11-13T21:21:13+00:00\",\"dateModified\":\"2023-11-14T20:29:06+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/radiant-heat-sensor\\\/#breadcrumb\"},\"inLanguage\":\"fr-CA\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/radiant-heat-sensor\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/radiant-heat-sensor\\\/#primaryimage\",\"url\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/artif_233.jpg\",\"contentUrl\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/artif_233.jpg\",\"width\":402,\"height\":242},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/radiant-heat-sensor\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Portfolio\",\"item\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Radiant heat sensor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#website\",\"url\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/\",\"name\":\"HVACR Heritage Centre\",\"description\":\"We are the virtual home to an unrivalled collection of heating and cooling inventions, devices, instruments, and technology.\",\"publisher\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-CA\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#organization\",\"name\":\"HVACR Heritage Centre\",\"url\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/787-Herit-toplogo.png\",\"contentUrl\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/787-Herit-toplogo.png\",\"width\":310,\"height\":223,\"caption\":\"HVACR Heritage Centre\"},\"image\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Radiant heat sensor - HVACR Heritage Centre","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/portfolio\/radiant-heat-sensor\/","og_locale":"fr_CA","og_type":"article","og_title":"Radiant heat sensor - HVACR Heritage Centre","og_description":"The \u201cProtectostat\u201d, a late 1940\u2019s radiant heat sensor for combustion safety control. It would set new standard for combustion safety for higher firing rate, oil atomizing heating systems found in large Canadian estate homes, institutions and small industrial applications. Sited directly on the fire, it used a black metal diaphragm to mechanically actuate a low voltage control system through a Minneapolis Honeywell \u201cProtectorelay\u201d, Minneapolis Honeywell, Type A, Circa 1948.","og_url":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/portfolio\/radiant-heat-sensor\/","og_site_name":"HVACR Heritage Centre","article_modified_time":"2023-11-14T20:29:06+00:00","og_image":[{"width":402,"height":242,"url":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2023\/11\/artif_233.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimation du temps de lecture":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/radiant-heat-sensor\/","url":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/radiant-heat-sensor\/","name":"Radiant heat sensor - HVACR Heritage Centre","isPartOf":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#website"},"primaryImageOfPage":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/radiant-heat-sensor\/#primaryimage"},"image":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/radiant-heat-sensor\/#primaryimage"},"thumbnailUrl":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2023\/11\/artif_233.jpg","datePublished":"2023-11-13T21:21:13+00:00","dateModified":"2023-11-14T20:29:06+00:00","breadcrumb":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/radiant-heat-sensor\/#breadcrumb"},"inLanguage":"fr-CA","potentialAction":[{"@type":"ReadAction","target":["https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/radiant-heat-sensor\/"]}]},{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/radiant-heat-sensor\/#primaryimage","url":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2023\/11\/artif_233.jpg","contentUrl":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2023\/11\/artif_233.jpg","width":402,"height":242},{"@type":"BreadcrumbList","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/radiant-heat-sensor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/hvacrheritage.dnmstaging.ca\/"},{"@type":"ListItem","position":2,"name":"Portfolio","item":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/"},{"@type":"ListItem","position":3,"name":"Radiant heat sensor"}]},{"@type":"WebSite","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#website","url":"https:\/\/hvacrheritage.dnmstaging.ca\/","name":"HVACR Heritage Centre","description":"Nous sommes la maison virtuelle d\u2019une collection in\u00e9gal\u00e9e d\u2019inventions, d\u2019appareils, d\u2019instruments et de technologies dans le domaine du chauffage et du refroidissement.","publisher":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/hvacrheritage.dnmstaging.ca\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-CA"},{"@type":"Organization","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#organization","name":"HVACR Heritage Centre","url":"https:\/\/hvacrheritage.dnmstaging.ca\/","logo":{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#\/schema\/logo\/image\/","url":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2023\/07\/787-Herit-toplogo.png","contentUrl":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2023\/07\/787-Herit-toplogo.png","width":310,"height":223,"caption":"HVACR Heritage Centre"},"image":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/cpt_portfolio\/20881","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/cpt_portfolio"}],"about":[{"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/types\/cpt_portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/comments?post=20881"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/media\/20882"}],"wp:attachment":[{"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/media?parent=20881"}],"wp:term":[{"taxonomy":"cpt_portfolio_group","embeddable":true,"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/cpt_portfolio_group?post=20881"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}