{"id":2759,"date":"2020-05-18T10:29:53","date_gmt":"2020-05-18T10:29:53","guid":{"rendered":"https:\/\/hvacrheritage.ca\/?post_type=cpt_portfolio&#038;p=2759"},"modified":"2023-11-07T18:54:22","modified_gmt":"2023-11-07T18:54:22","slug":"refrigeration-expansion-valve-ap204","status":"publish","type":"cpt_portfolio","link":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/portfolio\/refrigeration-expansion-valve-ap204\/","title":{"rendered":"Refrigeration expansion valve \u2018AP204\u2019"},"content":{"rendered":"<h3 class=\"wp-block-heading\">Refrigerant Flow Controls \u2013 Household<\/h3>\n\n\n\n<p>A mid 20th century, compact, spring compensated, adjustable, automatic expansion valve for use on \u201cdry evaporators\u201d, with tin coated, cast brass body, flange mounting and wrench pads, finely calibrated and rated for sulphur dioxide, methyl chloride and Freon 12 refrigerant [Incomplete Assembly] Automatic Products, Model AP204, circa 1944.<\/p>\n\n\n\n<p>Original manufacturer\u2019s installation and service instruction sheet; Inlet screen; Moisture proof, more robust metal cap and seal [not included]<\/p>\n\n\n\n<p>Technical Significance<br>An example of the new generation of compact, more precisely engineered and performing expansion valves emerging early in the 1940\u2019s, calibrated and engineered the wider range of refrigerants then in use, including mainly sulphur dioxide, menthol chloride and Freon 12<\/p>\n\n\n\n<p>Dramatises the major gains made by the industry over a period of less than 10 years, during a period of feverish research and development using the scant knowledge and experience available to workers in the field at the time, compare ID # 165 to 173<\/p>\n\n\n\n<p>This artifact of history tells the many stories of early adoption of this particular fluid flow technology, the automatic expansion valve. After a brief flurry of excitement over the use of more costly and delicate float operated devices, as a more efficient means of flow control, industry engineers would return to the automatic expansion valve in the early 30\u2019s. But by then the automatic expansion valve would be a smaller and much more precisely calibrated and efficient device. While the automatic expansion valve was less efficient in its effective use of evaporator surface than high and low side float systems [See HHCC Series 3.01 artifacts, ID # 175 and 176 for example], it had the advantage of reliability, maintainability and affordability, as well as serviceability.<\/p>\n\n\n\n<p><strong>Industrial Significance:<\/strong><br>Following W.W.II, in the 1940\u2019s, the refrigeration and air conditioning industry went through a second major growth spurt. By then it was armed with new technology, manufacturing and engineering know-how, as well as new materials to work with \u2013 much of it the results of war-time research, development and field practice.<\/p>\n\n\n\n<p>This valve in many ways characterizes the world change that had taken place, encouraging, allowing and facilitating many new refrigeration and air conditioning applications. These were especially evident in the emergence of sophisticated \u201cpackaged systems\u201d. Using the new chlorinated hydrocarbon refrigerants [e.g., Freon 12], the systems were smaller more compact, quieter and more user friendly.<\/p>","protected":false},"excerpt":{"rendered":"<p>A mid 20th century, compact, spring compensated, adjustable, automatic expansion valve for use on \u201cdry evaporators\u201d, with tin coated, cast brass body, flange mounting and wrench pads, finely calibrated and rated for sulphur dioxide, methyl chloride and Freon 12 refrigerant [Incomplete Assembly] Automatic Products, Model AP204, circa 1944.<\/p>","protected":false},"author":1,"featured_media":20485,"comment_status":"closed","ping_status":"closed","template":"","cpt_portfolio_group":[199,206],"class_list":["post-2759","cpt_portfolio","type-cpt_portfolio","status-publish","has-post-thumbnail","hentry","cpt_portfolio_group-refrigeration","cpt_portfolio_group-residential"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Refrigeration expansion valve \u2018AP204\u2019 - HVACR Heritage Centre<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/portfolio\/refrigeration-expansion-valve-ap204\/\" \/>\n<meta property=\"og:locale\" content=\"fr_CA\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Refrigeration expansion valve \u2018AP204\u2019 - HVACR Heritage Centre\" \/>\n<meta property=\"og:description\" content=\"A mid 20th century, compact, spring compensated, adjustable, automatic expansion valve for use on \u201cdry evaporators\u201d, with tin coated, cast brass body, flange mounting and wrench pads, finely calibrated and rated for sulphur dioxide, methyl chloride and Freon 12 refrigerant [Incomplete Assembly] Automatic Products, Model AP204, circa 1944.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/portfolio\/refrigeration-expansion-valve-ap204\/\" \/>\n<meta property=\"og:site_name\" content=\"HVACR Heritage Centre\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-07T18:54:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2020\/05\/artif_174.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"450\" \/>\n\t<meta property=\"og:image:height\" content=\"313\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Estimation du temps de lecture\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/refrigeration-expansion-valve-ap204\\\/\",\"url\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/refrigeration-expansion-valve-ap204\\\/\",\"name\":\"Refrigeration expansion valve \u2018AP204\u2019 - HVACR Heritage Centre\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/refrigeration-expansion-valve-ap204\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/refrigeration-expansion-valve-ap204\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/wp-content\\\/uploads\\\/2020\\\/05\\\/artif_174.jpg\",\"datePublished\":\"2020-05-18T10:29:53+00:00\",\"dateModified\":\"2023-11-07T18:54:22+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/refrigeration-expansion-valve-ap204\\\/#breadcrumb\"},\"inLanguage\":\"fr-CA\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/refrigeration-expansion-valve-ap204\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/refrigeration-expansion-valve-ap204\\\/#primaryimage\",\"url\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/wp-content\\\/uploads\\\/2020\\\/05\\\/artif_174.jpg\",\"contentUrl\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/wp-content\\\/uploads\\\/2020\\\/05\\\/artif_174.jpg\",\"width\":450,\"height\":313},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/refrigeration-expansion-valve-ap204\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Portfolio\",\"item\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/portfolio\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Refrigeration expansion valve \u2018AP204\u2019\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#website\",\"url\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/\",\"name\":\"HVACR Heritage Centre\",\"description\":\"We are the virtual home to an unrivalled collection of heating and cooling inventions, devices, instruments, and technology.\",\"publisher\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-CA\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#organization\",\"name\":\"HVACR Heritage Centre\",\"url\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-CA\",\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/787-Herit-toplogo.png\",\"contentUrl\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/wp-content\\\/uploads\\\/2023\\\/07\\\/787-Herit-toplogo.png\",\"width\":310,\"height\":223,\"caption\":\"HVACR Heritage Centre\"},\"image\":{\"@id\":\"https:\\\/\\\/hvacrheritage.dnmstaging.ca\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Refrigeration expansion valve \u2018AP204\u2019 - HVACR Heritage Centre","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/portfolio\/refrigeration-expansion-valve-ap204\/","og_locale":"fr_CA","og_type":"article","og_title":"Refrigeration expansion valve \u2018AP204\u2019 - HVACR Heritage Centre","og_description":"A mid 20th century, compact, spring compensated, adjustable, automatic expansion valve for use on \u201cdry evaporators\u201d, with tin coated, cast brass body, flange mounting and wrench pads, finely calibrated and rated for sulphur dioxide, methyl chloride and Freon 12 refrigerant [Incomplete Assembly] Automatic Products, Model AP204, circa 1944.","og_url":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/portfolio\/refrigeration-expansion-valve-ap204\/","og_site_name":"HVACR Heritage Centre","article_modified_time":"2023-11-07T18:54:22+00:00","og_image":[{"width":450,"height":313,"url":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2020\/05\/artif_174.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Estimation du temps de lecture":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/refrigeration-expansion-valve-ap204\/","url":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/refrigeration-expansion-valve-ap204\/","name":"Refrigeration expansion valve \u2018AP204\u2019 - HVACR Heritage Centre","isPartOf":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#website"},"primaryImageOfPage":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/refrigeration-expansion-valve-ap204\/#primaryimage"},"image":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/refrigeration-expansion-valve-ap204\/#primaryimage"},"thumbnailUrl":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2020\/05\/artif_174.jpg","datePublished":"2020-05-18T10:29:53+00:00","dateModified":"2023-11-07T18:54:22+00:00","breadcrumb":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/refrigeration-expansion-valve-ap204\/#breadcrumb"},"inLanguage":"fr-CA","potentialAction":[{"@type":"ReadAction","target":["https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/refrigeration-expansion-valve-ap204\/"]}]},{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/refrigeration-expansion-valve-ap204\/#primaryimage","url":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2020\/05\/artif_174.jpg","contentUrl":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2020\/05\/artif_174.jpg","width":450,"height":313},{"@type":"BreadcrumbList","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/refrigeration-expansion-valve-ap204\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/hvacrheritage.dnmstaging.ca\/"},{"@type":"ListItem","position":2,"name":"Portfolio","item":"https:\/\/hvacrheritage.dnmstaging.ca\/portfolio\/"},{"@type":"ListItem","position":3,"name":"Refrigeration expansion valve \u2018AP204\u2019"}]},{"@type":"WebSite","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#website","url":"https:\/\/hvacrheritage.dnmstaging.ca\/","name":"HVACR Heritage Centre","description":"Nous sommes la maison virtuelle d\u2019une collection in\u00e9gal\u00e9e d\u2019inventions, d\u2019appareils, d\u2019instruments et de technologies dans le domaine du chauffage et du refroidissement.","publisher":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/hvacrheritage.dnmstaging.ca\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-CA"},{"@type":"Organization","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#organization","name":"HVACR Heritage Centre","url":"https:\/\/hvacrheritage.dnmstaging.ca\/","logo":{"@type":"ImageObject","inLanguage":"fr-CA","@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#\/schema\/logo\/image\/","url":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2023\/07\/787-Herit-toplogo.png","contentUrl":"https:\/\/hvacrheritage.dnmstaging.ca\/wp-content\/uploads\/2023\/07\/787-Herit-toplogo.png","width":310,"height":223,"caption":"HVACR Heritage Centre"},"image":{"@id":"https:\/\/hvacrheritage.dnmstaging.ca\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/cpt_portfolio\/2759","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/cpt_portfolio"}],"about":[{"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/types\/cpt_portfolio"}],"author":[{"embeddable":true,"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/comments?post=2759"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/media\/20485"}],"wp:attachment":[{"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/media?parent=2759"}],"wp:term":[{"taxonomy":"cpt_portfolio_group","embeddable":true,"href":"https:\/\/hvacrheritage.dnmstaging.ca\/fr\/wp-json\/wp\/v2\/cpt_portfolio_group?post=2759"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}